ارسال سریع به سراسر ایران پشتیبانی 24/7
HAMMOND CT50A

ترانسفورماتور(ترانس) ترانس جریان (سی‌تی)

HAMMOND CT50A

Manufacturer Hammond
Mfr. Part Number CT50A
Electland Part Code 372445
Electland Part Number NYE_CT50A
Category Current Transformers
Description 5 A Current Sense Transformer Chassis Mount
Datasheet Download

Product Attributes

Category Transformers Current Transformers
Mounting Type Chassis Mount
type Non-Invasive (Solid Core)
Termination Style Wire Leads
Current Rating (Amps) 5 A
Size / Dimension 3.750" L x 1.750" W (95.25mm x 44.45mm)
Height - Seated (Max) 3.250" (82.55mm)
Turns Ratio 50:5
Rated input Current 5A
Current Ratio 50:5
Packaging Screw Terminals
Tariff Active False
ReachStatus REACH Unaffected
RohsStatus ROHS3 Compliant
MoistureSensitivityLevel Not Applicable
ExportControlClassNumber EAR99
HtsusCode 8504.31.2000
Weight 0.5g

Features

  • Toroidal design.
  • Equipped with 24-inch insulated secondary leads terminated with crimp ring connectors. Suitable for bare (uninsulated) primary conductors in circuits up to 600V (4KV hipot tested); also suitable for higher voltages when used with appropriately insulated conductors.
  • Secondary current of 5A for all units, compatible with standard AC ammeters with 5A range. All models include dual-hole mounting brackets.
  • UL E227616 Vol. 1, File No. X0DW2

Applications

  • To obtain a current measurement:
    1. Pass the wire carrying the current to be measured through the window of the current transformer (CT) (as the primary winding).
    2. Connect the CT secondary to an ammeter on the 5A range.
  • For higher accuracy or higher VA burden ratings:
    1. Select a CT whose primary turns are a multiple of the desired primary rating and that has the required accuracy or VA burden.
    2. Pass the wire carrying the current to be measured through the window a number of times equal to that multiple. This "winding" method restores the ratio to the desired primary rating. Example A: To achieve 1.2% accuracy at a 100:5 ratio under a 10VA burden, use a CT400 and pass 4 primary turns through the window. Example B: To obtain a 25:5 ratio, use a CT75 with 3 primary turns for 2% accuracy, or use a CT50 with 2 primary turns for 3.2% accuracy.

In-Stock Suppliers

NoyanElectronic
0 in stock
Supplier Part Number: NYE_CT50A

1 1
QTY USD TOMAN
1+$55.7915,490,330 تومان
200+$22.266,180,580 تومان
500+$21.525,975,120 تومان
1000+$21.155,872,390 تومان

Qty in reel: 1pcs/reel