ارسال سریع به سراسر ایران پشتیبانی 24/7
MAXIM MAX30001CWV+T

مدار مجتمع (آی سی) آی سی‌کاربرد ویژه

MAXIM MAX30001CWV+T

Manufacturer MAXIM
Mfr. Part Number MAX30001CWV+T
Electland Part Code 172158
Electland Part Number NYE_MAX30001CWV+T
Category Specialized ICs
Description Biopotential AFE 30-WLP (2.74x2.93)
Datasheet Download

Product Attributes

Category Integrated Circuits (ICs) Specialized ICs
type Biopotential AFE
Applications Heart Rate Monitoring
Mounting Type Surface Mount
Package / Case 30-WFBGA, WLBGA
Supplier Device Package 30-WLP (2.74x2.93)
Operating Temperature 0℃~+70℃
Voltage - Supply 1.1V~2V
S/N Ratio 97.7dB
interface SPI
Features Programmable gain;ESD protection
Number of Channels 2
Resolution (Bits) 18;512Hz
Data Rate 512Hz
Clock Frequency 32.768kHz;0Hz~12MHz
Voltage Reference Value 1V
Packaging WLP-30(2.7x2.9)
ReachStatus REACH Unaffected
RohsStatus ROHS3 Compliant
MoistureSensitivityLevel 1 (Unlimited)
ExportControlClassNumber EAR99
HtsusCode 8542.39.0070
Weight 0.275g

Introduction

The MAX30001 is a complete, biopotential and bioimpedance (BioZ), analog front-end (AFE) solution for wearable applications. It offers high performance for clinical and fitness applications, with ultra-low power for long battery life. The MAX30001 is a single biopotential channel providing electrocardiogram (ECG) waveforms, heart rate and pacemaker edge detection, and a single bioimpedance channel capable of measuring respiration. The biopotential and bioimpedance channels have ESD protection, EMI filtering, internal lead biasing, DC leadsoff detection, ultra-low-power, leads-on detection during standby mode, and extensive calibration voltages for builtin self-test. Soft power-up sequencing ensures no large transients are injected into the electrodes. Both channels also have high input impedance, low noise, high CMRR, programmable gain, various low-pass and high-pass filter options, and a high resolution analog-to-digital converter. The biopotential channel is DC coupled, can handle large electrode voltage offsets, and has a fast recovery mode to quickly recover from overdrive conditions, such as defi­ brillation and electro-surgery. The bioimpedance channel includes integrated programmable current drive, works with common electrodes, and has the flexibility for 2 or 4 electrode measurements. The bioimpedance channel also has AC lead off detection. The MAX30001 is available in a 30-bump wafer-level package (WLP), operating over the 0°C to +70°C com­ mercial temperature range.

Features

  • Can be Used in IEC 60601-2-47:2012 Compliant Systems
  • Clinical-Grade ECG and BioZ AFE with High Resolution Data Converter
  • 15.9 Bits ENOB with 3.1μVₚ₋ₚ (typ) Noise for ECG
  • 17 Bits ENOB with 1.1μVₚ₋ₚ Noise for BioZ
  • Better Dry Starts Due to Much Improved Real World CMRR and High Input Impedance
  • Fully Differential Input Structure with CMRR > 100dB
  • Offers Better Common-Mode to Differential Mode Conversion Due to High Input Impedance
  • High Input Impedance >10Ω for Extremely Low Common-to-Differential Mode
  • Minimum Signal Attenuation at the Input During Dry Start Due to High Electrode Impedance
  • High DC Offset Range of ±650mV (1.8V, typ) Allows to Be Used with Wide Variety of Electrodes
  • High AC Dynamic Range of 65mVₚ₋ₚ for ECG and 90mVₚ₋ₚ for BioZ Will Help Prevent Saturation in the Presence of Motion/Direct Electrode Hits
  • Longer Battery Life Compared to Competing Solutions
  • 85μW at 1.1V Supply Voltage for ECG
  • 158μW at 1.1V Supply Voltage for BioZ
  • Leads-On Interrupt Feature Allows to Keep the μC in Deep Sleep Mode Until Valid Lead Condition is Detected
  • Lead-On Detect Current: 0.7μA (typ)
  • Built-In Heart Rate Detection with Interrupt Feature Eliminates the Need to Run HR Algorithm on the µController
  • Robust R-R Detection in High Motion Environment at Extremely Low Power
  • Configurable Interrupts Allows the μC Wake-Up Only on Every Heart Beat Reducing the Overall System Power
  • High Accuracy Allows for More Physiological Data Extractions
  • 32-Word ECG and 8-Word BioZ FIFOs Allows the MCU to Stay Powered Down for 256ms with Full Data Acquisition
  • High-Speed SPI Interface
  • Shutdown Current of 0.6μA (typ)

Applications

  • Single-Lead Event Monitors for Arrhythmia Detection
  • Single-Lead Wireless Patches for In-Patient/Out-Patient Monitoring
  • Chest Band Heart Rate Monitors for Fitness Applications
  • Bio Authentication and ECG-On-Demand Applications
  • Respiration and Hydration Monitors
  • Impedance Based Heart Rate Detection

In-Stock Suppliers

NoyanElectronic
0 in stock
Supplier Part Number: NYE_MAX30001CWV+T

1 1
QTY USD TOMAN
1+$2.99830,190 تومان
10+$2.64733,010 تومان
30+$2.6721,900 تومان
100+$2.56710,790 تومان

Qty in reel: 2000pcs/reel