| Manufacturer | EATON |
|---|---|
| Mfr. Part Number | HPS-RR |
| Electland Part Code | 121122 |
| Electland Part Number | NYE_HPS-RR |
| Category | Fuseholders |
| Description | Linear Voltage Regulator IC Positive Fixed 1 Output 300mA 4-X2SON (1x1) |
| Datasheet | Download |
| Category | Circuit Protection Fuseholders |
|---|---|
| Mounting Type | Surface Mount |
| Package / Case | 4-XDFN Exposed Pad |
| Operating Temperature | -40°C ~ 125°C (TJ) |
| Output Type | Fixed |
| Supplier Device Package | 4-X2SON (1x1) |
| Output Configuration | Positive |
| Voltage - Input (Max) | 5.5V |
| Number of Regulators | 1 |
| Voltage - Output (Min/Fixed) | 1.8V |
| Voltage Dropout (Max) | 0.2V @ 300mA |
| Current - Output | 300mA |
| Current - Quiescent (Iq) | 141 µA |
| PSRR | 60dB ~ 45dB (1kHz ~ 1MHz) |
| Control Features | Enable |
| Protection Features | Over Current, Over Temperature, Under Voltage Lockout (UVLO) |
| ReachStatus | REACH Unaffected |
| RohsStatus | ROHS3 Compliant |
| MoistureSensitivityLevel | 1 (Unlimited) |
| ExportControlClassNumber | EAR99 |
| HtsusCode | 8542.39.0090 |
| Weight | 0.5g |
Panel-mount fuse holders for 13/32×15/16-inch to 1 1/16-inch and SC and CC class fuses. The fuse holder is panel-mount type, UL Listed (Listing No. IZLT2, File No. E14853), CSA Certified (Class 6225-01, File No. 47235), with a flammability rating of UL 94 HB. Electrical ratings: without UL Listing or CSA Certification, maximum current is 20A with quick-connect terminals; HPS models are rated 25A under CSA standards. For maximum panel thickness with the mounting flange in front of the panel, assuming Pollution Degree 3 per UL 840 (conductive pollution, or dry non-conductive pollution that becomes conductive due to expected condensation), excluding any sealing gasket; if the fuse holder load terminals are fully insulated (using UL-recognized VW-1 rated insulating heat shrink tubing), the intended environment is Pollution Degree 1 or 2, and the panel is a non-conductive material, a thicker panel may be used. Pollution Degree 2 normally has only non-conductive pollution, but temporary conductivity may occur due to condensation; Pollution Degree 1 has no pollution or only dry non-conductive pollution with no effect. With the mounting flange behind the panel, the maximum panel thickness is 5.08 mm/0.200 inch (flush with the knob ferrule).
| QTY | USD | TOMAN |
|---|---|---|
| 1+ | $10.17 | 2,823,740 تومان |
| 200+ | $3.94 | 1,093,960 تومان |
| 500+ | $3.8 | 1,055,090 تومان |
| 1000+ | $3.73 | 1,035,650 تومان |